| Data Sheet | ||
|---|---|---|
| Supply voltage | 3x400V | |
| DV Version |
3x230V |
|
| Output range | 25 A - 250 A | |
| Duty Cycle | 35% | 250 A |
| 60% | 190 A | |
| 100% | 130 A | |
| Open circuit voltage | 15.25 ÷ 26.5 VDC | |
| Frequency | 50 / 60 Hz | |
| Mains fuses (delayed action) | 10 A | |
| Max. connected power | 4.8 kW | |
| Recommended generator rating | 8.2 kW | |
| Cos j | 0.9 | |
| Protection classification | IP 21 s | |
| Insulation class | F | |
| Adjustement range | 11 step (7 Step for DV) | |
| Rolls | 2 | |
| Wire speed | 2 ÷ 20 m/min | |
| Torch connection | Euro | |
| Dinse | 25 mm2 | |
| Weight | 67 Kg | |
| Dimensions (WxLxH) | 330x900x820 mm | |
| Wire | Ø | 0.6 - 1.0 |
| Features | ||
| Pre gas/post gas | - | |
| Soft start | * | |
| Burn back | * | |
| Display | - | |
| DV version | * |